Please, if you need more support, cantact me again. The calbe for comunication the mmc star up or IBS is the same of S7, always try to comunication on 187 kby in the port of same of s7 and configure mmc start-up with nck=3 ,plc=2 and 187 kby, make the back up one only each time, first nck with compstion data, and then plc, bouth of files is in the binary mode, try not open ten for corruptthe file's.
#Winpcin Siemens software
in the software f10= start and Shift F9 = exit ,

The software mmc start up work of line it's too easy lock, and then turn off and turn on the notebook.
#Winpcin Siemens series
The mmc sart up or IBS for simodrive id good working off-line and then when you know the software you can go on-line for make the complete back-up of ne and plc : NC.ARC and PLC.ARC ( series start -up ), rememember put the general machine data MD 11210=0 and then make other backup with 11210=FF. In the port opi the speed of comunication is 1,5 mby and the address is other's. In the mmc start-up or IBS you can 2 point in the ncu for go on line, in the same port for s7, mpi and 187kby this valid for 810d/840d, for other port in the opi ( painel operator)in the nck port at 1,5 mby this is only for 840d, for 840di it's diferent (1,5 mby), and first you need to set the address for mmc start up before go on line, in the mpi port you must configure (MMC)softkey of mmc start up, plc=2, nck=3 and speed 187 kby. Maybe, I'dont know, we can use the for sent the files, I use this site is for sent a very big sotfware, i don't remember which the version of mmc start up i have, maybe i have for win 98, but you need the version the mmc star up for win xp or win2K, i see and need to study your sinucom nc for saiy to you if it's possible or not, i always use mmc start.
#Winpcin Siemens download
Which version of sinucom nc you have, sinucom arc, sinucom FFS, sinucom nc, ? cd rom with sinucom nc ?or give me the site where you made download for to see what you have? I dont' know where you can find the mmc start up, you have the sinucom nc? then you must ready for comunication in"map" network with pcu50/70, the pcu must be boot in mindows mode.this is not to easy, it's necessary experence.
#Winpcin Siemens drivers
The pcu50/70 only comunication in "netbios"protocol, you can fin it inside the cd od win xp ( 2 drivers)then must be load inside the pg and add in network protocol on win xp "netbios", the name of computer must be ANDUSER ( automation and drivers user) and the password "SUNRISE". , normaly is in F> mmc2 and in one file inside and you must look inside in the windows mode ( boot the pcu in win mode).Īnd you can make the backup of alarms in windows mode throu the network MAP, but in your pg with win xp it's necessary put 2 files. Por each pcu the file is in different position inside, for pcu20 you must go in the screen startup or service not remember, then selection text+ input and you have 2 languajes, in the pcu50/70 with hard disk i don't know where the manufacturer load it ,the name maby is xxx.

If it's necessary make a new project for your machine you must use the tool box of the same version of pcmcia card because after you load the program inside of your plc the plc goes to stop mode and you never know why goes to stop !this is valid for 840d/810d/840di, for the other's cnc are similary, see "table of compatibily"! in the site of 2) for the alarms text use winpcin in txt mode ( not binary mode) configure rs232 interface in the notebook and in the pcu20/50/70. If you load the tool box you can not open the hardware, or open with error.
#Winpcin Siemens install
OK ! The software said back up complete.Ītention !, for open the hardware in the project of S7 is necessary install the toolbox for 810d/840d /840di in the step 7 library, the tool box must be the same version of pcmcia card in the case of 840d, it's not absolut necessary for make upload but you can install tool box> =of pcmcia version, may be version 6.5, only apply setup and the tool box install alone, then you can see or open the hardware of the project upload of step7, if the toolbox not installated you can not open the hardware in the step 7 project!! OKK, you understand? It's necessary the tool box for open the hardware ! this valid for 801d/840d/840dI. I'm working for a very long time with 810d/840d/840di/, i don't know if i'm a teacher but i study very much and a lot of people talk with me.ġ) for make the backup (up-load the program) with s7 v5.3, the comunication in the pg-pc (notebook) (s7)interface must be in 187 kby, rack=o, mpi =2, you need open a new project, insert s7-300 station and then "upload station ", afther this you ( wait a 5 or 10 minutes) have a backup of plc program without of comentary.